This standard describes the materials and application of tape coating systems in
coating plants at fixed sites using coating techniques and equipment as recommended
by the tape coating manufacturer. For normal construction considerations, prefabricated
polyolefin tapes are applied as a three-layer...
Back to AWWA C214-07 Tape Coating Systems for the Exterior of Steel Water Pipelines
This standard describes the materials and application of tape coating systems in
coating plants at fixed sites using coating techniques and equipment as recommended
by the tape coating manufacturer. For normal construction considerations, prefabricated
polyolefin tapes are applied as a three-layer system consisting of liquid
adhesive, corrosion-preventive tape (inner layer), and mechanical-protective
tape (outer layer). This standard establishes the minimum requirements for tape
coating systems used on the exterior of steel water pipelines in the potable-water
supply industry. Continuous monitoring of all application procedures for the tape
coating systems shall be performed by the constructor. The major revisions made to the standard in this
edition include the following:
changes were made in Sec. 4.4, describing the pipe surface preparation procedure
using abrasive-blast-cleaning methods, along with consistent terminology for
abrasive blast cleaning, abrasive mix, and visual comparative standards;
a new section, Sec. 4.4.2.8, on weld height limits was added;
provisions for the use of heat-applied repair patches in accordance with
ANSI/AWWA C216 were added in Sec. 4.4.4; and,
provisions for the use of an electronic-magnetic thickness gauge were added
in Sec. 5.3.2.